Waveline Touch Patient Monitor with Touch-Screen
Price: On Request
Suggest Your Price
In Stock
Condition | |
---|---|
Warranty |
Description
User-friendly touch-screen patient monitor measures ECG, SpO2, NIBP, heart rate, temperature and respiration. Offers optional dual IBP, and EtCo2.
The fully-functional Waveline Touch features a 12.1′ color TFT display with a touch-screen interface. It features multi-lead ECG monitoring, ST segment monitoring and 72 hours trend data analysis.
Features:
- New – Optional Plug-In Anesthesia Gas Module expands measurement capabilities €” Anesthesia Gas Module
- New – Bigger time stamp in upper right corner
- New – Standby button
- New – Revised SpO2 pitch tone is still audible when SpO2 rate decreases
- New – Volume and Sounds are adjustable and now can be turned off completely
- New – Option to print Numerical Data Only
- New – Color of the waveforms can be changed
- EtCO2 Option allows compliance with ASA
- Available with optional dual invasive blood pressures, EtCO2, a battery and a built-in recorder.
- 12.1′ color TFT display with a touch-screen interface
- Multi-lead ECG monitoring
- Built-in battery (optional)
- NIBP list display
- OxyCRG dynamic view display
- Built-in thermal recorder
- Networkable with a central monitoring system via a wireless or wired network
- S-T Segment and 72 hours trend data analysis
- Compact design convenient for mobile monitoring
- Drug dose calculations
- Multi-lingual settings
Specifications:
Physical Weight & Dimensions | Weight: 5kg Height: ~11 inches |
Length: ~6-1/5 inches Width: ~12 3/5 inches |
Application | Neonatal, pediatric and adult patients | |
Operation Environment | Power Source – External AC power or internal battery AC Power – 100-240VAC, 50/60Hz, <,150VA |
Battery – Rechargeable Lead-Acid, Operating time under the normal condition (1 hour), Operating time after the first alarm of low battery (10 min.) |
Temperature | Working – 5°-40° C Storage – -20°-65° C |
|
Performance Specifications | Display – 12.1′ color TFT, Touch Screen Resolution – 800 A— 600 pixels Trace – 4, 6 or 8 waveforms ECG (I, II, III, aVR, aVL, aVF, V1-V6), PLETH, RESP, IBPx2, ETCO2 Indicator – Alarm indicator, Power indicator QRS beep and alarm sound |
Trend Time – 72 hours Recorder – Built-in, thermal array, 2 channels Record – Width 48mm Recorder – Paper 50mm Record – Speed 25mm/s, 50mm/s |
ECG | Input – 3-lead ECG cable and standard AAMI line for connection Input – (Optional) 5-lead ECG cable and standard AAMI line for connection Lead Choice – I, II, III, aVR, aVF, aVL, V Gain Choice – x0.5, x1.0, x2.0 Frequency Characteristic – 0.05-40 Hz ECG Waveforms – 7 channels |
Penetration Voltage – 4000VAC 50/60Hz Sweep Speed – 12.5, 25 and 50 mm/s HR Display Range – 30-300bpm Accuracy – ±1% or ±1bpm, whichever is greater Alarm Limit Range Setting – Upper limit 80-400bpm, Lower limit 20-150bpm |
RESP | Measure Method – RA-LL impedance Range – 0-120 rpm Accuracy – + 3 rpm |
Alarm Upper-lower Limit Setting – Upper limit 6-120 rpm, Lower limit 3-120 rpm Sweep Speed – 12.5 and 25 mm/s |
NIBP (Suntech) | Measuring Technology – Automatic oscillating measurement Cuff Inflating – <,30s-0-300 mmHg, standard adult cuff Measuring Period – AVE<,40s Mode – Manual, Auto, STAT Measuring Interval in AUTO Mode – 2 min-4 hrs Pulse Rate Range – 30-250 (bpm) |
Measuring Range – Adult/Pediatric Mode, SYS 40-250 (mmHg), DIA 15-200 (mmHg), Neonatal Mode, SYS 40-135 (mmHg), DIA 15-100 (mmHg) Resolution – 1mmHg Accuracy – Pressure, Maximum Mean error ±5mmHg, Max. Standard deviation 8mmHg Overpressure Protection – Adult Mode 280(mmHg), Neonatal Mode 150 (mmHg) Alarm Limit Setting – SYS 50-240 mmHg, DIA 15-180 mmHg |
TEMP | Range – 25°-50° C Accuracy – + 0.2 °C 25.0°-34.9° C, + 0.1° C 35.0°-39.9° C, + 0.2° C 40.0°-44.9° C, 0.3° C 45.0°-50.0° C Display Resolution – 0.1° C |
Alarm Upper-lower Limit Setting – Upper limit 0-50° C, Lower limit 0-50° C Channel – 2 channels Alarm Limit Setting – 10-50° C |
SPO2 | ASpO2 Anti-motion SpO2 SpO2% Range 0-100% SpO2 Accuracy + 2% 70-100%, nonmotion, + 3% 70-100%, motion Pulse Rate Range 30-250 bpm Pulse Rate Accuracy ±2 bpm (non-motion), ±3 bpm (motion) |
Alarm Upper-lower Limit Setting: Upper limit 70-100%, Lower limit 70-100% SpO2 Probe – Red Light LED Wavelength 660nm±5nm, Infrared Light LED Wavelength – 940nm±10nm |
IBP (Option) | Measurement Range – -10-300mmHg Channel – 2 channels Pressure Transducer Sensitivity, 5I?V/V/mmHg Impedance Range – 300-3000I© |
Transducer Sites – ART, PA, CVP, RAP, LAP, ICP Resolution – 1mmHg Accuracy – ±1mmHg or ±2%, whichever is greater Alarm range – -10-300mmHg |
EtCO2 (Option) | EtCO2 Option allows compliance with ASA Standards for Basic Anesthetic Monitoring (Effective July 1, 2011) Mode of Sampling – Sidestream Principle of Operation -Non-dispersive infrared (NDIR) single beam optics, dual wavelength, no moving parts CO2 Measurement Range – 0 to 150 mmHg (0 to 19.7%, 0 to 20 kPa) CO2 Calculation Method – BTPS (Body Temperature Pressure Saturated) CO2 Resolution – 0.1mmHg(0-69mmHg), 0.25mmHg(70-150mmHg) |
CO2 Accuracy – 0-40 mmHg ± 2 mmHg, 41-70 mmHg ± 5% of reading, 71-100 mmHg ± 8% of reading, 101-150 mmHg ± 10% of reading, Above 80 breath per minute ± 12% of reading Sampling Rate – 100Hz Respiration Rate – 2-150 bpm Respiration Rate Accuracy – ±1 breath Response Time – <,3 seconds – includes transport time and rise time Inspired CO2 Measurement Range – 3-50 mmHg |