Waveline Touch Patient Monitor with Touch-Screen

Price: On Request Suggest Your Price

In Stock

In Stock

Condition

Warranty

DRE Waveline Touch

Description

User-friendly touch-screen patient monitor measures ECG, SpO2, NIBP, heart rate, temperature and respiration. Offers optional dual IBP, and EtCo2.

The fully-functional Waveline Touch features a 12.1′ color TFT display with a touch-screen interface. It features multi-lead ECG monitoring, ST segment monitoring and 72 hours trend data analysis.

Features:

  • New – Optional Plug-In Anesthesia Gas Module expands measurement capabilities €” Anesthesia Gas Module
  • New – Bigger time stamp in upper right corner
  • New – Standby button
  • New – Revised SpO2 pitch tone is still audible when SpO2 rate decreases
  • New – Volume and Sounds are adjustable and now can be turned off completely
  • New – Option to print Numerical Data Only
  • New – Color of the waveforms can be changed
  • EtCO2 Option allows compliance with ASA
  • Available with optional dual invasive blood pressures, EtCO2, a battery and a built-in recorder.
  • 12.1′ color TFT display with a touch-screen interface
  • Multi-lead ECG monitoring
  • Built-in battery (optional)
  • NIBP list display
  • OxyCRG dynamic view display
  • Built-in thermal recorder
  • Networkable with a central monitoring system via a wireless or wired network
  • S-T Segment and 72 hours trend data analysis
  • Compact design convenient for mobile monitoring
  • Drug dose calculations
  • Multi-lingual settings

Specifications:

Physical Weight & Dimensions Weight: 5kg
Height: ~11 inches
Length: ~6-1/5 inches
Width: ~12 3/5 inches
Application Neonatal, pediatric and adult patients
Operation Environment Power Source – External AC power or internal battery
AC Power – 100-240VAC, 50/60Hz, &lt,150VA
Battery – Rechargeable Lead-Acid, Operating time under the normal condition (1 hour), Operating time after the first alarm of low battery (10 min.)
Temperature Working – 5°-40° C
Storage – -20°-65° C
Performance Specifications Display – 12.1′ color TFT, Touch Screen
Resolution – 800 A— 600 pixels
Trace – 4, 6 or 8 waveforms ECG (I, II, III, aVR, aVL, aVF, V1-V6), PLETH, RESP, IBPx2, ETCO2
Indicator – Alarm indicator, Power indicator QRS beep and alarm sound
Trend Time – 72 hours
Recorder – Built-in, thermal array, 2 channels
Record – Width 48mm
Recorder – Paper 50mm
Record – Speed 25mm/s, 50mm/s
ECG Input – 3-lead ECG cable and standard AAMI line for connection
Input – (Optional) 5-lead ECG cable and standard AAMI line for connection
Lead Choice – I, II, III, aVR, aVF, aVL, V
Gain Choice – x0.5, x1.0, x2.0
Frequency Characteristic – 0.05-40 Hz
ECG Waveforms – 7 channels
Penetration Voltage – 4000VAC 50/60Hz
Sweep Speed – 12.5, 25 and 50 mm/s
HR Display Range – 30-300bpm
Accuracy – ±1% or ±1bpm, whichever is greater
Alarm Limit Range Setting – Upper limit 80-400bpm, Lower limit 20-150bpm
RESP Measure Method – RA-LL impedance
Range – 0-120 rpm
Accuracy – + 3 rpm
Alarm Upper-lower Limit Setting – Upper limit 6-120 rpm, Lower limit 3-120 rpm
Sweep Speed – 12.5 and 25 mm/s
NIBP (Suntech) Measuring Technology – Automatic oscillating measurement
Cuff Inflating – &lt,30s-0-300 mmHg, standard adult cuff
Measuring Period – AVE&lt,40s
Mode – Manual, Auto, STAT
Measuring Interval in AUTO Mode – 2 min-4 hrs
Pulse Rate Range – 30-250 (bpm)
Measuring Range – Adult/Pediatric Mode, SYS 40-250 (mmHg), DIA 15-200 (mmHg), Neonatal Mode, SYS 40-135 (mmHg), DIA 15-100 (mmHg)
Resolution – 1mmHg
Accuracy – Pressure, Maximum Mean error ±5mmHg, Max. Standard deviation 8mmHg
Overpressure Protection – Adult Mode 280(mmHg), Neonatal Mode 150 (mmHg)
Alarm Limit Setting – SYS 50-240 mmHg, DIA 15-180 mmHg
TEMP Range – 25°-50° C
Accuracy – + 0.2 °C 25.0°-34.9° C, + 0.1° C 35.0°-39.9° C, + 0.2° C 40.0°-44.9° C, 0.3° C 45.0°-50.0° C
Display Resolution – 0.1° C
Alarm Upper-lower Limit Setting – Upper limit 0-50° C, Lower limit 0-50° C
Channel – 2 channels
Alarm Limit Setting – 10-50° C
SPO2 ASpO2 Anti-motion SpO2
SpO2% Range 0-100%
SpO2 Accuracy + 2% 70-100%, nonmotion, + 3% 70-100%, motion
Pulse Rate Range 30-250 bpm
Pulse Rate Accuracy ±2 bpm (non-motion), ±3 bpm (motion)
Alarm Upper-lower Limit Setting: Upper limit 70-100%, Lower limit 70-100%
SpO2 Probe – Red Light LED Wavelength 660nm±5nm, Infrared Light LED
Wavelength – 940nm±10nm
IBP (Option) Measurement Range – -10-300mmHg
Channel – 2 channels
Pressure Transducer Sensitivity, 5I?V/V/mmHg
Impedance Range – 300-3000I©
Transducer Sites – ART, PA, CVP, RAP, LAP, ICP
Resolution – 1mmHg
Accuracy – ±1mmHg or ±2%, whichever is greater
Alarm range – -10-300mmHg
EtCO2 (Option) EtCO2 Option allows compliance with ASA Standards for Basic Anesthetic Monitoring (Effective July 1, 2011)
Mode of Sampling – Sidestream
Principle of Operation -Non-dispersive infrared (NDIR) single beam optics, dual wavelength, no moving parts
CO2 Measurement Range – 0 to 150 mmHg (0 to 19.7%, 0 to 20 kPa)
CO2 Calculation Method – BTPS (Body Temperature Pressure Saturated)
CO2 Resolution – 0.1mmHg(0-69mmHg), 0.25mmHg(70-150mmHg)
CO2 Accuracy – 0-40 mmHg ± 2 mmHg, 41-70 mmHg ± 5% of reading, 71-100 mmHg ± 8% of reading, 101-150 mmHg ± 10% of reading, Above 80 breath per minute ± 12% of reading
Sampling Rate – 100Hz
Respiration Rate – 2-150 bpm
Respiration Rate Accuracy – ±1 breath
Response Time – &lt,3 seconds – includes transport time and rise time
Inspired CO2 Measurement Range – 3-50 mmHg