Waveline Pro Touch-Screen Anesthesia Monitor

Price: On Request Suggest Your Price

In Stock

In Stock

Condition

Warranty

DRE Waveline Pro

Description

Superior performance with a high-resolution touch-screen

The DRE Waveline Pro displays as many as eight colorful waveforms on a crisp, high-resolution 15-inch touch-screen that optimizes the speed of patient care. The user can make quick screen adjustments, set default settings, alarm limits, and manage up to 72 hours of detailed patient data. Designed for a fast paced work environment, the Waveline Pro patient monitor offers an extremely simple and adaptable user interface. Patient information along with vital-signs settings can be quickly modified to meet the needs of a patient’s changing condition, converting from a basic vital signs monitor, to a continuous bed side monitor, to an operating room monitor.

This patient monitor offers standard measurements of: non-invasive blood pressure, 3-lead or 5-lead ECG with arrhythmia detection, motion tolerant SpO2, Temperature, and Respiration rate. End-tidal CO2, Anesthetic Agent measurement, Cardiac Output and Invasive blood pressure are available options.

The Waveline Pro monitor offers several connective solutions to network multiple monitors and/or manage patient data on an electronic medical records platform or a HL7-based hospital information system. It offers Ethernet and RS-232 connections with an open source communication protocol, and it is HL7 compliant. The HL7 network protocol will allow for all patient information and vital sign trends to be transferred and stored on a hospital information system.

Capnography is outpacing Pulse Oximetry as the new standard of care in outpatient surgery procedures.

Features:

  • Optional Integrated DrA¤ger Anesthesia Gas Bench expands measurement capabilities
  • Optional agent bench is compact and part of main unit. All in one monitor!
  • Large (15′), touch-screen with high-resolution flat panel display
  • Displays as many as eight waveforms
  • Multi-lead simultaneous ECG monitoring
  • Automatically set alarm limits
  • Graphical and tabular trending
  • Color-coded alarms
  • Patient data entry
  • Networking capability
  • Works with EMR and wireless telemetry systems
  • Large time stamp in upper right corner
  • Standby button
  • Volume and Sounds are adjustable and can be turned off completely
  • Option to print Numerical Data Only
  • Color of the waveforms can be changed
  • Battery backup (two removable batteries)
  • Available with a built-in thermal printer

Specifications:

Performance Display: 15-inch color touch-screen
Trace: 8 waveforms
Indicator:

  • Alarm indicator
  • Power indicator
  • QRS beep and alarm sound

 

Trend time: 1 – 72 hour
Recorder:

  • Built-in, thermal array, 3 channels
  • Record width: 48mm
  • Recorder paper: 50mm
  • Record speed: 25mm/s, 50mm/s

 

ECG Input: 5-lead ECG cable and standard AAMI line for connection
Lead Choice: I, II, III, aVR, aVF, aVL, V, V1-V6, TEST
Gain Choice : x0.5, x1, x2, x4
Frequency Characteristic: 0.05 ~ 35 HZ (+3dB)
ECG Waveforms: 7 channels
Penetration Voltage: 4000VAC 50/60Hz
Sweep Speed: 12.5, 25, 50 and 100 mm/sec (left to right or right to left)
HR Display Range: 30 ~ 300bpm
Accuracy: ±1bpm or ±1%, whichever is greater
Alarm Limit Range Setting:

  • Upper limit 100 ~ 200bpm,
  • Lower limit 30 ~ 100bpm

 

RESP Measure Method: RA-LL impedance
Range: 0 ~ 120 rpm
Accuracy: ±3 rpm
Alarm Limit Setting:

  • Upper limit 6 ~ 120 rpm,
  • Lower limit 3 ~ 120 rpm

Sweep Speed: 12.5, 25, 50 and 100 mm/sec (left to right or right to left)

NIBP Measuring Technology: automatic oscillating measurement
Cuff Inflating: &lt,30s (0 ~ 300 mmHg, standard adult cuff)
Measuring Period: AVE&lt,40s
Mode: Manual, Auto
Measuring Interval in AUTO Mode: 2 min ~ 4 hrs
Pulse Rate Range: 30 ~ 250 (bpm)
Adult/Pediatric Mode: SYS: 40 ~ 250 (mmHg)
DIA :15 ~ 200 (mmHg)
Neonatal Mode: SYS: 40 ~ 135 (mmHg)
DIA : 15 ~ 100 (mmHg)
Accuracy:

  • Maximum Mean error: ±5mmHg
  • Maximum Standard deviation: 8mmHg

 

TEMP Range: 25 ~ 50 (°C)
Accuracy:

  • ± 0.2°C (25.0 ~ 34.9°C)
  • ± 0.1°C (35.0 ~ 39.9°C)
  • ± 0.2°C (40.0 ~ 44.9°C)
  • ± 0.3°C (45.0 ~ 50.0°C)

 

Display Resolution: 0.1°C
Alarm Limit Setting:

  • upper limit 0 ~ 50°C,
  • lower limit 0 ~ 50°C

Channel: 2 channels

SpO2 ASpO2: Anti-motion SpO2
SpO2% Range: 0-100%
SpO2 Accuracy:

  • ±2% (70 ~ 100%, non-motion)
  • ±3% (70 ~ 100%, motion)

Pulse Rate Range: 30-250 bpm
Pulse Rate Accuracy:

  • ±2 bpm (non-motion
  • ±3 bpm (motion)

 

Alarm Limit Setting:

  • Upper limit 70 ~ 100%,
  • Lower limit 70 ~ 100%

SpO2 Probe:

  • Red light LED wavelength
  • 660nm±5nm
  • Infrared light LED wavelength
  • 940nm±10nm
IBP Measurement Range: -50 ~ 300mmHg
Channel: 2 channels
Pressure Transducer: sensitivity, 5A‚uV/V/mmHg
Impedance Range: 300 ~ 3000I‰
Transducer Sites: ART, PA,CVP, RAP, LAP, ICP
Unit: mmHg/kPa selectable
Resolution: 1mmHg
Accuracy: ±1mmHg or ±2%, whichever is greater
AlarmRange: -10 ~ 300mmHg
EtCO2 (Optional) CO2 Measurement Range: 0 ~ 99mmHg
Accuracy:

  • ±2mmHg (0 ~ 38mmHg)
  • 39-99mmHg ±5% of reading +0.08% for every 1mmHg (above 38mmHg)

Sampling Rate: 50 ml/min

Initialization Time: 30 seconds (typical), reaches ±5% steady-state accuracy within 3 minutes.
Respiration Rate: 0 ~ 150 breaths/min
Mode: adult, neonate
Cardiac Output (Optional) Measurement Method: Thermodilution Method
CO2 Measurement Range:

  • C.O.: 0.1 to 20 L/min
  • TB: 23 to 43
  • TI: 0 to 27

Resolution:

  • C.O.: ±5% or ±0.1 L/min, whichever is greater, as measured using electornically generated flow curves.
  • TB, TI: 0.1

 

Accuracy:

  • ±5 or ±0.1 L/min, whichever is greater, as measured using electronically generated flow curves.
  • TB, TI ±0.1 (without sensor)

Alarm Range: TB 23 to 43
Repeatability: C.O. ±2% or 0.1 L/min, whichever is greater, as measured using electronically generated flow curves.

Anesthetic Agents (Optional) Method: Infrared absorption
Gas Sorts: Halothane, Isoflurane, Enflurane, Sevoflurane, Desflurane, CO2, N2O, O2 (optional Automatic Agent ID)
Measurement Range:

  • Halothane, Isoflurane: 0 – 8.5%
  • Enflurane, Sevoflurane: 0 – 10%
  • Desflurane: 0 – 20%
  • CO2: 0 – 10%
  • N2O: 0 – 100%
  • O2: 0 – 100%

 

Bias:

  • Halothane, Isoflurane, Enflurane, Sevoflurane, Desflurane: ±(0.15 Vol% + 15% rel.)
  • CO2: ±(0.5 Vol% + 12% rel.)
  • N2O: ± (2 Vol% + 8% rel.)
  • O2: ±3 Vol%
Networking Industry standard 802.11b/g wireless network
Power Source: External AC power or internal battery
AC Power: 100 – 240VAC, 50/60Hz, 150VA
Battery: Built-in and rechargeable lithium ion
Operating TIme: 3+ hours
Environmental Temperature:

  • Operating: 5° – 40° C
  • Storage: -20° – 65° C
Humidity Range:

  • Operating: ‰¤,80 %
  • Storage: ‰¤80 %
Other Standard Feature OxyCRG, drug dose calculation, cascading ECG, On screen NIPB trends (up to 250 readings), user set defaults, Arrhythmia detection, ST segment

Additional information

Condition

Warranty

Write us an email!

    Your name *

    Your email *

    Your message *

    5 × two =

    We will call you back soon!

      Your name *

      Your phone number *

      Your email *

      Subject of the request *

      five × 2 =

      Contact us

      Suggest Your price

        5 + eleven =

        Are you looking for equipment that isn’t listed on paxamedical?
        We will gladly help you find what you are looking for.

          8 − one =