Description
Siemens ARCADIS Orbic 3D Features
The ARCADIS Orbic 3D mobile C-arm system provides fast scan times matched with enhanced image quality. The ARCADIS generates 2D images of the human anatomy in only 30 seconds in 1K2 resolution or 60 seconds for 100 2D images. ARCADIS Orbic 3D C-arm machines can be equipped with the direct 3D navigation interface NaviLink 3D, or choose the integrated optical navigation platform NaviVision 3D
ARCADIS Orbic’s software is designed to support the entire clinical workflow, from patient registration to image documentation. Patient data can seamlessly be transferred from the hospital information system to your C-arm worklist. Two distinctive features of the ARCADIS Orbic mobile C-arm are true isocentric orbital movement and 190° orbital movement with 95° overscan. Due to this technology, this unit does not require horizontal or vertical readjustment in order to keep viewing area centered and focused.
Siemens ARCADIS Orbic 3D Specifications
Dimensions
- Diameter, cm (in) (Wheels) 23, 15 (9, 6)
- H x W x D of C-arm Frame, cm (in) (Image Processing and Storage): 183 x 80 x 215 (72 x 31.5 x 84.5)
- Weight, kg (lb) (Display): 348 (765) chassis, 190 (418) monitor cart
- Cassette Holder Sizes (Focal spot size, mm): 24 x 3024 x 30 cm
- Free Space, cm (in) (C-Arm): 78 (31)
- Depth, cm (in) (PA Gantry): 73 (29)
- Panning Movement (C-Arm) 10
- Rotation (C-Arm) 190 ( 95)
- Horizontal Travel, cm (in) (C-Arm): 20 (7.9)
- Pivot Rotation, (C-Arm) 190
C-Arm
- Isocentric C-arm movement with integrated cables and electromagnetic brakes
- Orbital movement 190° (± 95°)
- Angulation ± 190°
- Horizontal movement 20 cm (7.9”)
- Immersion depth 73 cm (28.7”)
- Swivel range ± 10°
- Vertical travel 40 cm (15.7”), motorized
- Source-I.I. distance 98 cm (38.5”)
- Free space 78 cm (30.7”)
X-ray generator / tube
- Max. pulsed output 2.3 kW
- Inverter control frequency 15 kHz to 30 kHz
- kV range 40 kV to 110 kV
- Fluoroscopy 0.2 mA to 15.2 mA (max. 1000 W)
- Digital Radiography 0.2 mA to 23 mA (max. 1000 W)
- Pulsed Fluoroscopy up to 23 mA
- Pulse width min. 7 ms Pulse rate up to 8 f/s, up to 15 f/s*
- Power Mode enables temporary max. output in continuous fluoroscopy and pulsed fluoroscopy
Operating Data
- Power Requirements: 100 V, 110 V, 120 V, 127 V, 200 V, 230 V, 240 V, (± 10%), 50/60 Hz (± 1 Hz)
- Device Fusing (Internal): 100 V to 127 V 20 A slow-blow fuse 200 V to 240 V 15 A slow-blow fuse
Environmental Conditions
- Temperature range + 15°C to + 35°C
- Relative humidity 15% to 75%, non-condensing
- Barometric pressure 700 hPa to 1060 hPa
General
- Pulses Per Sec (Monitor): p to 15
- Ma Range (Imaging System): 0.2 – 23
- Pulsed Fluoroscopy (X-Ray Generator): Yes
- Kv Range (X-Ray Generator): 40
- Aec (X-Ray Generator): mAs
- Tube Power Rating, kw @ 100 kvp (Maximum Output): 2.3
- Power Requirements: 110-240 VAC
Video / Images
- Monitor Size, cm (in) (Maximum Object): 18 dual TFT flat-panel monitors
- H x W x D of C-Arm Frame, cm (in) (Image Processing and Storage): 183 x 80 x 215 (72 x 31.5 x 84.5)
- Video Storage (Image Processing and Storage): Digital memory, disk
- Image Matrix Size (Image Processing and Storage): 2.3
- Last Taken Image hold (Image Processing and Storage): Yes
- Frame Integration (Image Processing and Storage): 0-32 frames
- Max. # of Images (Image Processing and Storage): 10,000 on hard disk; ~300 on CD; both are standard