Description
Siemens ARCADIS Avantic Features
The current ARCADIS generation takes you to a completely new level of clinical excellence. From image quality to operability, from versatility to efficiency, the innovative features of ARCADIS Avantic are aimed to set new benchmarks – with outstanding functionalities that make excellent imaging a snap and an overall ergonomic concept that will redefine your clinical workflow in many fields of practice. ARCADIS Avantic features large power reserves with a generator power of 25 kW, high tube currents of up to 250 mA, and high endurance through 2.57 MHU (Mega Heat Units) heat capacity.
- Powerful performance
- Precise Imaging with larger field of view
- Easiest Operation
- Improved Clinical Workflow
- Maximum flexibility in data handling
- Improved Serviceability and comprehensive maintenance options
Siemens ARCADIS Avantic Specifications
C-Arm
- Orbital Movement: 132° (- 42° to + 90°)
- Angulation: ± 190°
- Horizontal Movement: 20 cm
- Immersion Depth: 73 cm
- Swivel Range: ± 1:0°
- Vertical Rravel: 38 cm, motorized
- Source-I.I. Distance: 100 cm
- Free Space: 78 cm
X-Ray Generator / Tube Unit
POWERPHOS High-Frequency Generator
- Power Output: 15 kW
- Max. Pulsed Output: 25 kW
- Inverter Control Frequency: 15 kHz to 35 kHz
- kV Range: 40 kV to 125 kV
- Digital Radiography: up to 250 mA
- Fluoroscopy: 0.2 mA to 15.2 mA (max. 1000 watts)
- Power Mode: enables temporary max. output in continuous fluoroscopy
- Pulsed Fluoroscopy: up to 67 mA
- Pulse Rate: up to 8 p/s, up to 15 p/s
- DCM* (Digital Cine Mode): up to 250 mA
- Minimum Pulse Width: 7 ms
- Pulse Rate: up to 30 p/s
- Heat Storage Capacity of POWERPHOS Housing: 1,900,000 J, 2,565,000 HU
Single Tank WIth Dual-Focus Rotating-Anode Tube
- Focal Spot Nominal Value: 0.3 / 0.5
- Nominal Voltage: 125 kV
- Heat Storage Capacity of Anode: 200,000 J, 270,000 HU
- Optical Anode Angle: 10°
- Inherent Filtratin: ≥ 2.5 mm Al; 0.1 mm Cu
- Anode Drive: up to 10,800 RPM
Collimator System
- Iris Diaphragm: for concentric, radiation-free collimation
- Semi-Transparent Slot Diaphragm: for symmetric, radiation-free collimation, with unlimited rotation
Operating Data
- Power requirements: 100 V, 110 V, 120 V, 127 V, 200 V, 230 V, 240 V (± 10%); 50/60 Hz (± 1 Hz)
- Device fusing (internal): 100 V to 127 V 20 A slow-blow fuse 200 V to 240 V 15 A slow-blow fuse
Environmental Conditions (Operating)
- Temperature Range: + 15°C to + 35°C
- Relative Humidity: 15% to 75%, non-condensing
- Barometric Rressure: 700 hPa to 1060 hPaM
Weight
- C-arm Chassis: 347 kg (without accessories)
- Trolley With Integrated UPS: 188 kg (without accessories)
Data Transfer and Documentation
- Image storage: 60,000 images on hard disk in 1K2 matrix
- WLAN: WLAN-Client module with Ethernet connection for wireless transmission of DICOM image data, e.g. to a PACS
- DICOM Offline Media (CD/DVD):
- For documenting images on CD/DVD in DICOM and bmp format
- DICOM Viewer for viewing patient images on a PC can be written to CD/DVD
- USB 2.0: Support for e.g. data exchange with external devices
- External monitor connections:
- Live monitor (L):
- Video splitter output for connecting an external live monitor
- Reference monitor (R):
- Video splitter output for connecting an external reference monitor
- VGA interface (splitter), 1 x 15 pin VGA (no galvanic separation)
- Printer: Digital printers for printing on film or paper
- HIPAA: Security and Privacy (Health Insurance Portability and Accountability Act)
- Key switch:
- X-ray release can be disabled with a key switch to prevent unauthorized use
- When disabled, the system can still be used as a viewing station and for image processing