Description

GE Versamed iVent 201 Features

The GE Versamed iVent 201 ventilator has the versatility and capability of larger and more costly ventilators. This ventilator is a compact, portable, multi-featured microprocessor-controlled ventilator. The iVent ventilator features a turbine-powered air source and a rechargeable internal battery that provide freedom from wall air and power outlets. It has a well-organized and easy-to-read screen that allows for rapid control and continuous real-time monitoring of patient ventilation. Optional waveform and diagnostic software package display pressure and flow waveform data, loops, trends, and logged totals in a variety of graphic and numerical modes.

  • Adaptive Bi-Level (NIV).
  • Preset parameters by patient weight.
  • Apnea backup ventilation.
  • Adjustable rise time.
  • Easy Exhale.
  • Sigh breath.
  • 100% O2 suction.

 

GE Versamed iVent 201 Specifications

Dimensions

  • Height: (33 cm)
  • Width: (24 cm)
  • Depth: (26 cm)
  • Weight: Up to (12.6 kg)

Ventilation Modes

  • Assist/Control (A/C)
    • Volume Controlled (A/C)
    • Pressure Controlled (A/C)
  • Synchronized Intermittent Mandatory Ventilation (SIMV)
    • Volume Controlled SIMV (Vctrl)
    • Pressure Controlled SIMV (Pctrl)
  • Continuous Positive Airway Pressure (CPAP) with Pressure Support Ventilation (PSV)

O2 Supply Specifications

  • High Pressure: Pressure Range 40–75psi (2.8-5.1 bar). Warning: The exact oxygen pressure which the iVent 201 uses depends on the version you have. Check the back label for the pressure levels of your unit.
  • Low Pressure: Maximum flow 15L/min or 0.5 psi

Ventilation Performance and Parameters

  • Respiratory Rate: 1 – 12 ±1, 12 – 80 ± 2 bpm
  • Tidal Volume: 50-2000 mL
  • Accuracy of Tidal Volume Delivery: ±10% or ±10 mL whichever is greater
  • Accuracy of Exhale Tidal Volume Measurement: ±15% above 100 mL from actual reading or ±10 cc below 100 mL
  • Inspiratory Pressure Limit: 5 to 80 ±5 cmH2O
  • Inspiratory Time: Adaptive Time or 0.2 to 3 ±10% sec
  • Peak Flow (PIF): Adaptive Flow or to 120 ±10% L/min Spontaneous to 180 ±10% L/min
  • Oxygen Mix (FiO2 ): 21% to 100% ±10% of the set value or ±3% absolute, whichever is greater
  • PEEP: 0 to 40 ±1 cmH2O or ±10%, whichever is greater
  • Trigger Sensitivity: 1 to 20 L/min Flow, Off – 0.5 to – 20 cmH2O Pressure, Off
  • PSV: 0 to 60 ±10% cmH2O
  • Positive Pressure Relief Valve: 80 cmH2O
  • Pneumatic Nebulizer: 5 to 240 minutes
  • Controlled Pressure: 5 to 80 cmH2O ±5 cmH2O
  • FiO2 at Power up: 21%, 40%, 60%, 100% (configurable)
  • Configurable Humidifier Setting (Purging Cycle): HME (10 minute), Heated (1 minutes), Off

Power Supply

  • External AC: 100 to 240 V, 50 to 60 Hz, Max 1.6 A
  • External DC: 12 to 15 V, Max 8.5 A
  • Internal battery: Sealed lead-acid 12 V (7.8 Ah) (rechargeable)
  • Operating time: Depending on ventilator settings and impedance – standard internal up to 2 hours, optional extended internal up to 4 hours and optional external up to 8 hours.

Oxygen Supply

  • High pressure supply: 40 to 75 psi (2.8 to 5.1 bar)
  • Low pressure: Max 15 L/min or 0.5 psi

Environmental

  • Operating temperature: 0 to 50° C
  • Storage temperature: –15 to 70° C
  • Relative humidity: 15 to 95% at 30° C
  • Water/dust resistance: IP54 (splash proof)
  • Atmospheric pressure: 430 to 825 mm Hg (15,000 feet)
  • Vibration:
    • IEC 68-2-6 and IEC 68-2-34
    • mIL-STD-810E
  • Shock:Total external sound level: 40 to 45 dBa at one meter
    • IEC 68-2-27 (100 g)
    • MIL-STD-810E

 

Ventilation Performance and Controlled Parameters

  • Respiratory rate: 1 to 80 bpm
  • Tidal volume: 50 to 2,000 ml
  • Inspiratory pressure limit: 5 to 80 cm H2O
  • Inspiratory time: Adaptive I-Time or 0.2 to 3 sec
  • Esens: 10-90%
  • Rise time: Mid/high/max/auto
  • Peak flow: Adaptive Flow* or 1 to 120 L/min; Spontaneous up to 180 L/min
  • Oxygen mix (FiO2): 21 to 100%
  • PEEP: 0 to 40 cm H2O
  • Trigger sensitivity: 1 to 20 L/min flow sensitivity –0.5, to –20 cm H2O pressure sensitivity
  • PSV: 0 to 60 cm H2O
  • Positive pressure relief valve: 80 cm H2O
  • Synchronized nebulizer: 5 to 240 min

Monitoring and Displayed Parameters

  • Airway pressure (analog bar graph & numerical)
  • Total breath rate
  • I:E ratio
  • Exhaled tidal volume
  • Exhaled minute volume
  • Peak flow
  • Inspiratory time
  • Electrical power source (AC/external DC/internal DC)
  • Battery level
  • Pressure, flow and volume Waveforms software package:Trending of monitored data (72 hours)
  • Real-time pressure and flow waveforms
  • Waveform history brows
  • Respiratory mechanics (C, R, MAP, RR/Vt)SpO2
  • Pressure, flow and volume loops

Additional information

Brand

Condition

Year

Write us an email!

    Your name *

    Your email *

    Your message *

    4 × four =

    We will call you back soon!

      Your name *

      Your phone number *

      Your email *

      Subject of the request *

      15 + 20 =

      Contact us

      Suggest Your price

        8 + 4 =

        Are you looking for equipment that isn’t listed on paxamedical?
        We will gladly help you find what you are looking for.

          two × two =