/

GE OEC 9900 ELITE

Price: On Request Suggest Your Price

In Stock

In Stock

Brand

Condition

Year

Brands:: GE Healthcare

Description

GE OEC 9900 Elite Features

The GE OEC 9900 Elite C-arm uses a proprietary no-mask or motion tolerant subtraction technique to produce vascular images not previously possible on a mobile platform. The GE OEC 9900 Elite uses advanced image processing that is faster than alternative technologies and applies specific processing algorithms or different “bandwidths” to accentuate what you want to see and attenuate what you don’t.

The Elite’s image processing power is 100 times greater than older OEC C-Arm models, utilizing Dynamic Range Management. It is capable of producing 1k x 1k high-resolution images. For vascular imaging, it offers the Motion Tolerant Subtraction technique, a feature not previously available on a mobile unit.

  • Precision imaging Dynamic Range Management (DRM) for uncompromised image quality.
  • Touchscreen controls
  • Proprietary “no mask” or Motion Tolerant Subtraction (MTS) technique produces vascular images not previously possible on a mobile platform. Capable to perform a complete extremity run-off with a single injection and single run.
  • Unique X-ray tube and cooling system that allows for full-resolution imaging for longer periods of time.
  • HD flat panel monitors on an articulating arm allow comfortable viewing of precise images.
  • Remote service connectivity to enable system performance diagnostics.
  • 1k x 1k high resolution imaging technology on a mobile system.

GE OEC 9900 Elite C-Arm Specifications

X-ray System

Generator

  • 60kHz high frequency
  • 15kW power
  • Up to 120kVp
  • Up to 75mA for radiographic film exposure
  • Continuous high level fluoro (HLF) up to 20mA
  • Digital spot up to 75mA
  • Digital cine pulse
    • 15 or 30 pulses per second, 60 Hz
    • 12 or 25 pulses per second, 50 Hz
    • Up to 150mA
    • 10ms pulse width
  • Full power from standard wall outlet
  • Patented battery buffered design

X-ray Tube

  • Rotating anode X-ray tube
  • 0.3 and 0.6 nominal focal spots
  • Anode heat capacity: 300,000 HU
  • Anode cooling rate: 85,000 HU/min.
  • Housing heat capacity: 1,600,000 HU
  • Housing cooling rate:
    • 9” I.I. Super C- 22,500 HU/min
    • 12” I.I. – 22,500 HU/min

Digital Image Rotation

  • Digitally adjusts image display
  • Automatic image update
    • Image rotation
    • Image reversal (side-to-side)
    • Image invert (top-to-bottom)
  • Image positioning without additional exposure

Preview Collimator

  • On-screen collimator position indication
  • PreView iris collimator
  • PreView Tungsten rotatable double leaf collimator
  • Adjusts collimators without X-ray exposure

Fluoro Mode

  • kVp range: 40 -120
  • mA range:
    • 0.2 – 10 normal mode
    • 1.0 – 20 HLF (high level fluoro)
  • Auto and manual fluoro modes
  • AutoTrak ABS varies mA, kVp, camera gain

Pulsed Fluoro Mode

  • kVp range: 40 – 120
  • mA range: 0.2 – 10
  • Pulse rate: 1, 2, 4, 8
  • Pulse width: 25 or 50ms
  • AutoTrak ABS, mA, kVp, camera gain
  • Reduces X-ray dose to patient and operator

High Level Pulsed Fluoro

  • kVp range: 40 – 120
  • mA range: 1 – 40
  • Pulse rate: 1, 2, 4, 8
  • Pulse width: 25 or 50ms
  • AutoTrak ABS, mA, kVp, and camera gain

Digital Spot Mode

  • kVp range: 40 – 120
  • mA range: Up to 75
  • Automatic exposure termination and automatic image save

Radiographic Mode

  • mA range: up to 75
  • mAs range: up to 300
  • Computer controlled exposure time
  • Optional film cassette holder
    • 10” x 12” (24cm x 30cm) for 9” I.I.
    • 14” x 14” (35cm x 35cm) for 12” I.I.

Video Imaging System

9″ Image Intensifier

  • Tri-mode 9”/6”/4.5” (23cm/15cm/11cm) image intensifier
  • Minimum central resolution (at monitor):
    • 9” (23cm): 2.2 lp/mm
    • 6” (15cm): 3.0 lp/mm
    • 4.5” (11cm): 3.5 lp/mm
  • DQE: 65% (typical)

12″ Image Intensifier

  • Tri-mode 12”/9”/6” (31cm/23cm/15cm) image intensifier
  • Minimum central resolution (at monitor):
    • 12” (23cm): 1.6 lp/mm
    • 9” (15cm): 2.2 lp/mm
    • 6” (11cm): 2.6 lp/mm
  • DQE: 65% (typical)

Precision Imaging with Dynamic Range Management (DRM)

  • Preset Imaging Profile: Orthopedic
  • Enhances features of interest while attenuating background noise

AutoTrak Automatic Brightness Stabilization (ABS)

  • Automatically seeks the subject anatomy anywhere within the imaging field and selects the optimum imaging technique
  • Automatically adjusts to anatomical size and location
  • Provides uniform image quality throughout the entire image
  • Simplifies operation

Image Quality Features

  • Smart Window
    • Dynamically senses the collimator position and automatically adjusts brightness and contrast to produce high image quality
  • Smart Metal
    • Allows user to adjust automatic brightness and contrast sensitivity levels to metal
    • Provides optimum image quality even when metal is introduced to the field
  • Tungsten Collimator
    • Dense collimator limits X-ray exposure area
    • Reduces scatter radiation
    • Improves image detail

Video Camera

  • High resolution 1k x 1k CCD camera
  • Full frame capture
  • Motorized rotation
  • On-screen orientation indicator (real-time feedback without fluoro)
  • Left-right image reversal
  • Top-bottom image invert

Video Display

  • Dual 19” (48cm) display anti-glare, LCD flat panel monitors mounted on an articulating arm
    • 22” horizontal travel
    • 7° up/10° down
    • Monitors viewable from all four sides of workstation
    • Horizontal and vertical viewing angle 170°
  • 1200 CD/M2 maximum brightness
  • Touch screen system control
  • 1280 x 1024 high resolution monitors
  • Integrated color monitor for display of VGA, DVI, DVI-D, S-VHS, and SDISD formats

Additional information

Brand

Condition

Year

Wishlist 0
Open wishlist page Continue shopping

Suggest Your price

Are you looking for equipment that isn’t listed on paxamedical?
We will gladly help you find what you are looking for.

    [aios_captcha]