/

DRAGER Savina 300 Select Anesthesia Ventilator

Price: On Request Suggest Your Price

The Dräger Savina® 300 Select (in this configuration) combines the independence and power of a turbine-driven ventilation system with sophisticated ventilation modes. It’s broad variety of features and accessories supports a patient range from babies* to adults. The large colour touch screen and intuitive operating system that concentrates on established high class features make configuration and operation very simple.

In Stock

In Stock

Brand

Condition

442185f7eab4
Brands:: Drager

Description

The Drager Savina 300 Select combines the independence and power of a turbine- powered ventilation system with cutting edge ventilation modes. For the first time Drager offers a ventilator with oxygen therapy and Automatic Tube Compensation which where just for intensive care in the past. The Savia 300 Select operates independently for a centra power and gas supply making more flexible in a hospital setting. The ventilator is suitable for invasive and non-invasive therapy for acute and chronic care of patient from neonates to adults. The Drager Savina 300 select was designer to meet the ventilation needs for the most critically ill patients and flexible to be used anywhere in the hospital.

The 300 Select uses ambient air to filter through the ventilation system. The ventilator system keeps the reparatory gas at a permanently high flow delivery of up to 250 l/min. The ventilator can react quickly to pressure fluctuations and compensate for possible leakages in the case of patients ventilated with a mask. The large color touch screen design and the intuitive operating system make operation simple.

  • Sophisticated ventilation modes for critically ill patients (e.g. PC-APRV, VC-MMV)
  • Automatic Tube Compensation ATC reduces the work of breathing for intubated patients with spontaneous breathing
  • Stress-free spontaneous breathing with excellent trigger response time due to the turbine
  • Free breathing with AutoFlow in volume constant ventilation at a minimum pressure level
  • Non-invasive ventilation (NIV) available in all modes with a very quick response times to patient efforts
  • Extended graphic capabilities with loops, trends and logbook
  • Pediatric ventilation with enhanced trigger detection

Savina 300 Select Specifications

 

Dimensions (without trolley)

  • Height: (383 mm)
  • Width: (460 mm)
  • Depth: (364 mm)
  • Weight: (26 kg)
  • Diagonal Screen size: 30.5 cm TFT color touch screen

Ventilation Modes

  • VC-CMV / VC-AC
  • VC-SIMV
  • VC-MIMV
  • PC-APRV
  • PC-BIPAP1 / PC-SIMV+
  • PC-AC
  • SPN-CPAP

Enhancements

  • AutoFlow – Automatic adaption of the inspiratory flow in volume oriented ventilation modes
  • NIV – Non Invasive Ventilation with optimized alarm systems and automatic leakage compensation
  • Capnography – Mainstream CO2 measurement
  • MonitoringPlus – Loops, Trends, user Logbook
  • LPO – Low Pressure Oxygen, independent oxygen supply, e.g. with an O2 concentrator
  • Nurse call – Connection for transmitting alarm signals to a central, alarm system
  • Automatic tube compensation ATC – Automatic tube compensation regulates the airway pressure to the tracheal level
  • O2 Therapy – Continuous flow is applied via an oxygen mask, a hood or nasal cannula for patients with independent breathing

General

  • Patient type: Adult, pediatric
  • Respiratory rate: 2/min to 80/min
  • Inspiration time: 0.2 to 10 s
  • Tidal volume: 0.05 to 2.0 L, BTPS2) with option PediatricPlus 0.02 to 2.0 L
  • Inspiratory pressure:: 1 to 99 mbar (or hPa or cmH2O)
  • PEEP/interm. PEEP 0 to 50 mbar (or hPa or cmH2O)
  • Pressure support/ΔPsupp: 0 to 50 mbar (or hPa or cmH2O) (relative to PEEP)
  • Flow acceleration: 5 to 200 mbar/s (or hPa/s or cmH2O/s)
  • O2-concentration: 21 to 100 Vol. %
  • Trigger sensitivity (Flow trigger): 1 to 15 L/min
  • Inspiratory termination criterion: 5 to 75 % PIF (peak inspiratory flow)
  • PC-APRV (optional):
    • Inspiratory time Thigh 0.2 to 22.0 s
    • Expiratory time Tlow 0.1 to 22.0 s
    • Inspiratory pressure Phigh 1 to 95 mbar (or hPA or cmH2O)
    • Expiratory pressure Plow 0 to 50 mbar (or hPA or cmH2O)

Displayed Measured Values

  • Airway pressure measurements Max. airway pressure, plateau pressure, mean airway pressure, PEEP 0 to 99 mbar (or hPa or cmH2O)
  • Minute volume (MV): Total MV, spontaneous MV 0 to 99 L/min, BTPS
  • Tidal volume: Inspiratory VT, expiratory VTe, VTspon 0 to 3999 mL, BTPS
  • Total respiratory rate: Total and spontaneous respiratory rate, 0 to 150/min
  • Inspiratory O2-concentration: 21 to 100 % Vol.
  • End-tidal CO2 concentration: EtCO2 0 to 100 mmHg (or 0 to 13.2 Vol% or 0 to 13.3 kPa)
  • Breathing gas temperature: 18 to 48 °C
  • Curve displays: Paw(t), Flow (t), Tidal volume (t), CO2 (t)
  • Ventilation ratio (I:E): 1:150 to 150:1
  • Compliance C: 0.5 to 200 mL/mbar (or mL/hPa or mL/cmH2O)
  • Resistance R: 3 to 300 mbar/L/s (or hPa/L/s or cmH2O/L/s)
  • Leakage minute volume MVleak: 0 to 100 %
  • Rapid shallow breathing RSB: 0 to 9999 (1/min/L)
  • Special Maneuvers (optional):
    • Intrinsic PEEP PEEPi 0 to 100 mbar (or hPa or cmH2O)
    • Exp. Hold

Alarms

  • Airway pressures: high / low
  • Expiratory minute volume: high / low
  • Tidal volume: high / low
  • Apnea-alarm time: 15 to 60 sec
  • Spontaneous breathing frequency: high
  • Inspiratory O2-concentration: high / low
  • Inspiratory breathing gas temperature: high
  • EtCO2: high / low

Performance Data

  • Maximum (continuous) inspiratory flow: 250 L/min
  • Valve response time T0…90: ≤ 5 ms
  • Control principle: time-cycled, volume-controlled, pressure limited
  • Safety valve opening pressure: 120 mbar (or hPa or cmH2O)
  • Emergency valve: automatically enables spontaneous breathing with filtered ambient air if air and O2 supply should fail.
  • Automatic gas switch-over function if O2 supply fails
  • Output for pneumatic medication nebulizer: synchronized with inspiration
  • Leak compensation:
    • optimized patient-ventilator synchrony adjusts the flow trigger and the inspiratory termination criteria for leaks.
    • tube application: up to 10L/min
    • NIV VC-modes: up to 25 L/min
    • NIV PC-modes: unlimited

Operating Data

  • Mains power connection: 100 V to 240 V, 50/60 Hz
  • Current consumption: max. 1.3 A at 240 V, max. 3.4 A at 100 V
  • Battery: internal typically 45 min (optional extension up to 5 h)
  • Turbine exchange interval: 8 years, with no limit in operating hours during this interval

Digital Machine Outputs

  • Digital output and input via an RS 232 C interface
  • Dräger MEDIBUS and MEDIBUS.X

Gas Supply

  • Air Turbine technology
  • O2 gas supply 3 bar (43.5 psi) – 10 % up to 6 bar (87 psi)

Additional information

Brand

Condition

Write us an email!

    Your name *

    Your email *

    Your message *

    3 × three =

    We will call you back soon!

      Your name *

      Your phone number *

      Your email *

      Subject of the request *

      fifteen + two =

      Contact us

      Suggest Your price

        19 − three =

        Are you looking for equipment that isn’t listed on paxamedical?
        We will gladly help you find what you are looking for.

          18 − 14 =